Indo Anushka Engineering Steam · Air · Water — Est. 1999 Get a quote

Home  /  Catalog  /  Thermodynamic Steam Trap

TD-Series

Thermodynamic Steam Trap

Compact disc trap for steam mains drainage and superheat service, tolerant of high pressure and freezing.

Product overview

A disc-type trap with a single moving part, used where robustness and compactness matter more than close temperature control.

The problem it solves

Steam main drip points need a trap that survives high pressure, superheat and outdoor conditions without seizing or freezing.

Working principle

Condensate lifts the disc and discharges. Flash steam forming beneath the disc raises velocity, dropping pressure under the disc and snapping it shut until the flash condenses.

Applications

  • Steam main and header drip points
  • Superheated steam lines
  • Outdoor and freezing-risk locations

Advantages

  • One moving part — simple and serviceable
  • Handles superheat and high pressure
  • Compact and freeze tolerant

Specifications

  • Size range15 NB to 25 NB
  • Max pressure42 bar g
  • Max temperature400 °C
  • Body materialCS / SS 420
  • ConnectionsScrewed / socket weld / flanged

Get a quote

Send us the line conditions. We will size it and quote it.

Pressure, temperature, flow and medium — that is all we need to come back with a sized solution, a datasheet and a price.

Enquire