Home  /  Catalog  /  Mutiny® PTC / CPTC

PTC-Series

Mutiny® PTC / CPTC

Pump-trap combination that traps under positive differential and pumps when the equipment stalls.

Product overview

PTC and CPTC combine condensate pumping and steam trapping in one arrangement, so a single installation covers both operating regimes of a modulating heat exchanger — draining normally when pressure allows, and pumping when it does not.

The problem it solves

On equipment with a modulating steam inlet, the steam-space pressure falls as the control valve throttles. Below the point where it can overcome the return-line backpressure, condensate stops leaving. The exchanger floods, control becomes unstable and the tubes are exposed to waterhammer and corrosion. This is the stall condition.

Working principle

While the steam-space pressure exceeds the backpressure, the unit passes condensate as a trap. When differential is lost, the float admits motive steam or air and the same body displaces the accumulated condensate into the return line, then vents and refills.

Applications

  • Heat exchangers and reactors with modulating steam control
  • Temperature-controlled equipment prone to stall
  • Submerged coils and jacketed vessels
  • Installations where a separate pump and trap are impractical

Specifications

  • MotiveSteam or compressed air
  • Max motive pressure10 bar g
  • Max temperature198 °C
  • Body materialCI / CS
  • ConnectionsFlanged

Get a quote

Send us the line conditions. We will size it and quote it.

Pressure, temperature, flow and medium — that is all we need to come back with a sized solution, a datasheet and a price.

Enquire