Home  /  Catalog  /  MTRPS

MF-Series

MTRPS

Combined flash and condensate recovery system engineered for maximum thermal recovery and minimum steam loss.

Product overview

MTRPS packages flash separation, condensate collection and pumping into one recovery system, so both the flash steam and the hot condensate leaving a process are captured and put back to work rather than vented and drained.

The problem it solves

High-pressure condensate released to a lower pressure flashes, and that flash is usually vented to atmosphere. The vent plume is visible energy leaving the plant, and the hot condensate underneath it is often dumped as well — taking treated water and its heat content with it.

Working principle

Condensate is collected and admitted to a flash vessel where the pressure drop separates flash steam from liquid. The flash is taken off at low pressure for reuse in a suitable low-pressure user, while the remaining hot condensate is returned by pump or pump-trap to the boiler house or to a receiving process.

Applications

  • Centralised condensate and flash-steam recovery
  • Multi-user plants with distinct high and low pressure steam levels
  • Boiler-house feed water preheating
  • Two-stage flash recovery configurations

Specifications

  • Design pressureto suit duty, typically up to 16 bar g
  • MaterialCS / SS 316
  • ConnectionsFlanged
  • TestingHydro tested, PMI verified
  • SizingFlash load and low-pressure demand required

Get a quote

Send us the line conditions. We will size it and quote it.

Pressure, temperature, flow and medium — that is all we need to come back with a sized solution, a datasheet and a price.

Enquire