Direct steam injection hot water system

Open-tank and CIP heating using a Thermoject® injector, chosen where a heat-transfer surface would foul and where heating has to be rapid.

The application

Water heating in an open tank or a CIP circuit, previously done by open steam sparge — noisy, uneven, and losing steam through the vent.

What was engineered

A Thermoject® venturi injector arranged so steam condenses completely inside the mixing section, with temperature control on the steam admission and the circuit sized to give even tank temperature.

Result on the plant

Heating brought under control with no exchanger surface to scale or clean, and the vent plume removed. Temperature response and steam consumption figures for the installed arrangement are available on request.

Get a quote

Send us the line conditions. We will size it and quote it.

Pressure, temperature, flow and medium — that is all we need to come back with a sized solution, a datasheet and a price.